Unipower 52 AMP 2.5kw Rectifier Module Guardian Series Fmp25.48

Unipower 52 Amp 2.5kW Rectifier Module Guardian Series FMP25.48OverviewThe Guardian FMP25.48 52 amp rectifier incorporates resonant technology to reduce component stresses, providing increased system reliability and a best-in-class efficiency. The rectifier features a wide input operating 

Featured Products

Unipower 52 Amp 2.5kW Rectifier Module Guardian Series FMP25.48

Overview

The Guardian FMP25.48 52 amp rectifier incorporates resonant technology to reduce component stresses, providing increased system reliability and a best-in-class efficiency. The rectifier features a wide input operating voltage range to maximize power availability within demanding utility power environments.
These compact 52 amp rectifiers support up to 12.5kW in a 1RU 23" shelf. A wide variety of distribution options are available to provide the maximum system flexibility for a wide range of communications applications that demand efficiency, reliability, and flexibility including wireless base stations, remote switches, and broadband access.

Features and Options

Power density of up to 27W/in³
Rugged input voltage range
Thermal protection
Hot-swappable
92.5% typical efficiency
International standards compliance

Specifications

 
INPUT
VoltageOperating Range: 85-275VAC
Permitted variation: 85-300VAC
(L-PE and N-PE <250VAC)
Current<12.6A @ 240VAC
<17.2A @ 110VAC
Frequency47-63Hz
Power Factor>0.98
FuseTwo 25A fast blow (L & N)
 
OUTPUT
Voltage Range46-57.6VDC
Power2500W at ≥180VAC
1400W at 110VAC
1007W at 85VAC
Current48V NOMINAL

52.1A at ≥180VAC
29.2A at 110VAC
21.0A at 85VAC
53.5V FLOAT

46.7A at ≥180VAC
26.2A at 110VAC
18.8A at 85VAC
Derating15.7W/Vin from 180-85Vin
Efficiency>92.5%
ToleranceVout ±1.0%
Transient Response±5% at load variation 10-90% or 90-10%
20ms recovery
Load Sharing<5% of nominal current
Ripple<100mV p-p (BW 20 MHz)
Psophometric<2mV, according to CCITT norms
 
STANDARDS
Inrush CurrentETSI ETS 300 132-1
HarmonicsEN61000-3-2
EMCETSI EN300 386 V.1.3.2
EN61000-6-1, EN61000-6-2
EN61000-6-3, EN61000-6-4
EN55024 performance criterion A
EN55022 Class B
Telcordia NEBS GR1089
EnvironmentalStorage: ETSI EN300 019-2-1
Transport: ETSI EN300 019-2-2
Operation: ETSI EN300 019-2-3
Damp Heat: IEC60068-2-78
MIL-STD-810D section 507.2
Earthquake: GR 63 Core Zone 4
 
MECHANICAL
Dimensions, inches (mm)4.2 W x 14.0 D x 1.6 H (107 W x 355 D x 41 H)
Weight4.6lbs. (2.1kg)
CoolingFan-cooled, speed controlled
Insulation4.25kVDC primary-secondary
2.12kVDC primary-ground
0.2kVDC secondary-ground
EnclosureIP20
Mounting19in/23in x 1U subrack
up to 4/5 modules
 
GENERAL
ProtectionShort circuit
automatic current/power limiting
input/output overvoltage
thermal
AlarmsFan failure
Short circuit/arcing protection
High temperature/output voltage
Low output voltage
Input voltage out of range
Low fan speed (warning)
Internal communication failure
LED IndicatorsGreen: AC normal operation
Yellow steady: Low fan speed, High temperature
Yellow flashing: Comms. failure
Red: Module alarm / shutdown
Audible Noise (nominal input)<45dBA @ ≤25°C (50% load)
<60dBA (100% load)
Operating Temperature-40°C to +75°C up to 2000m
Reduced spec -40°C to -20°C
Derated output power from 55°C
linear derating to 75°C
For 3000m altitude derated by 5°C
Storage Temperature-60°C to +85°C
MTBF @ 25°C (without fan)>273,000 hours to MIL-HDBK-217F-2

1RU Power shelf Specifications
 
INTERFACE   /  SIGNALING
AddressingFor controller supervision each module position is addressed via DIP switches. Each switch can set 4-bit binary address, which means up to 16 Power Shelves (with up to 64 modules) can be supervised. Addressing is performed by setting the four bits to ON or OFF (ON=1, OFF=0).
CommunicationInternal Communication bus RS485
DESIGN STANDARDS
EMCIEC/EN61000-4-6; GR-1089; IEC/EN61000-4-3; EN55022/CISPR 22 Class B; FCC E222CFR
SafetyUL60950-1 CSA60950-1
EN60950-1 (UL approval only for input voltage levels 120 VAC / 250 VAC) IEC60950-1 CB report
CE-mark for LVD/EMI
GENERAL
Environmental  ImmunityIEC/EN60068-2-64 - 1993-05-28; IEC/EN60068-2-27 - 1987-06-15;
IEC/EN60068-2-27 - 1987-06-15; IEC/EN60068-2-29 - 1987-03-30
StorageETSI EN 300 019-2-1
TransportETSI EN 300 019-2-2
OperationETSI EN 300 019-2-3
Damp HeatIEC60068-2-78
Operating Temperature and Altitude-40°C to +55°C up to 2000m; Reduced specification: -40°C to -20°C
Extended Temperature and AltitudeLinear derating from 100% to 70% maximum power at 55 to 65°C Reduced ambient temperatures by 5°C at 3000m
CoolingDesigned for fan cooled, speed controlled modules (front to rear airflow)
Module ConfigurationHot-swappable modules (N+1)
InsulationBasic: from input to chassis Reinforced: from input to output
EnclosureIP21
Dimensions, inches (mm)XG1948G: 19.0 (483) W x 1.75 (44.5) H x 15.1 (384) D
XG2348G: 23.0 (584) W x 1.75 (44.5) H x 15.1 (384) D
XG1900G: 19.0 (483) W x 1.75 (44.5) H x 16.1 (409) D
XG2300G: 23.0 (584) W x 1.75 (44.5) H x 16.1 (409) D
Weight (no modules)XG1948G: 11.0 lb (5.0 kg)
XG2348G: 13.2 lb (6.0 kg)
XG1900G: 13.2 lb (6.0 kg)
XG2300G: 14.3 lb (6.5 kg)
Mounting19" or 23"
ApplicationXG1948G & XG2348G - 48V only
XG1900G & XG2300G - dual 48V & 24V or 24V only

Shelf Ordering Guide
 
MAX. POWERAPPLICATIONRECTIFIER POSITIONSRACK WIDTHPART NUM- BER
8kW48V only419"XG1948G
10kW523"XG2348G
8kWDual 48/24V419"XG1900G
10kW523"XG2300G

Shelf Accessories
 
PART NUMBERDESCRIPTION
XGB-01-GBlank cover plate for empty slot.

1-157379-G
Bus Bar hardware kit for single shelf applications; consisting of set of screws and washers for attaching DC power cables. Must be ordered with each shelf used in standalone applications.

1-155302-G
Bus Bar hardware kit for parallel shelf applications; consisting of DC bus link bars and set of screws and washers for attaching DC power cables. Must be ordered with each shelf used in parallel applications.

 